Following is a list of some of the reclosers we have available. For further information or pricing
on any of these, just email us your details with the inventory number of the unit you are interest in,
(from the left hand column headed Stock), and we can send a quote to you.
Stock Voltage Amps Description
S13341 38000 560 KYLE 38KV TYPE VWVE38 VACUUM IN OIL RECLOSER, ELECTRONIC CONTROL.
CLOSING SOLENOID NOMINAL VOLTAGE 22-24.9KV, OPERATING RANGE
+/-15%. TYPE B SENSING CTS. INTERRUPTING CURRENT 12KA,
CONTINUOUS CURRENT 560A.
S13351 38000 560 KYLE TYPE 38KV RVE OIL RECLOSER WITH ELECTRONIC CONTROL. MAX
INTERRUPTING CURRENT 6KA. RATED CONTINUOUS CURRENT 560A.
CLOSING SOLENOID 33KV, OPERATING RANGE +/-15%. TYPE B SENSING
CTS(RATIO 1000/1).
S13381 38000 15 MCGRAW EDISON 38KV RECLOSER. CLOSING SOLENOID 33KV, OPERATING
RANGE +/-15%. COIL DATA, CONTINUOUS CURRENT 15A, MIN TRIP
CURRENT 30A, MAX INTERRUPTING CURRENT 1500A. GROUND TRIP
SEQUENCE MIN TRIP 10A, CURVE 1 NO OP 2, CURVE 3 NO OP 3.
S13391 38000 0 MCGRAW EDISON 38KV RECLOSER. CLOSING SOLENOID 22KV, CONTINOUS
CURRENT 35A, MIN TRIP 70A, MAX INTERRUPTING CURRENT 2100A.
OPENING SEQUENCE 3 CURVE B, GROUND TRIP 10A, CURVE 2 NO OP 3.
S9661 38000 0 KYLE 38KV RATED RECLOSER TYPE RV,
CURRENTLY FITTED WITH 22KV CLOSING COIL, 10A EF TRIP
200A O/C TRIP
RATED 100A CONTINUOUS
S11641 33000 560 MCGRAW EDISON 33KV RECLOSER.
OPERATING VOLTAGE RANGE +/- 15%
COIL DATA: CONT CURRENT 15A, MIN TRIP CURRENT 30AMP, MAX INT
CURRENT 1500A

McGraw Edison Type RV Recloser
S13361 33000 50 MCGRAW EDISON 33KV TYPE RV OIL RECLOSER, HYDRAULIC CONTROL.
CLOSING SOLENOID 22-24.9KV, OPERATING RANGE +/-15%. COIL DATA
CONTINUOUS CURRENT 50A, MIN TRIP CURRENT 100A, MAX INTERRUPTING
CURRENT 3000A. OPENING SEQUENCE 3 CURVE C, GROUND TRIP SEQUENCE
MIN TRIP 10A, CURVE 1 NO. OP 2, CURVE 3 NO OP 3.
S13321 27000 560 KYLE 27KV VACUUM RECLOSER, TYPE VWVE27. MAX INTERRUPTING
CURRENT 12KA, RATED CONTINUOUS CURRENT 560A. CLOSING SOLENOID
NOMINAL VOLTS 11KV. EQUIPPED WITH TYPE B SENSING CT'S.
S601 25800 100 MCGRAW EDISON SINGLE PHASE AUTOMATIC RECLOSER, IMPULSE WITHSTAND
150KV, MAX DES. VOLT 25.8KV. COIL DATA: CONT CURRENT v 15A & o
100A, MIN TRIP CURRENT v 30A & o 200A, NOM VOLTAGE 2.4 TO 23KV,
MAX INT CURRENT v 600A & o 2500A.
S605 25800 100 MCGRAW EDISON SINGLE PHASE AUTOMATIC RECLOSER, IMPULSE WITHSTAND
150KV, MAX DES. VOLT 25.8KV. COIL DATA: CONT CURRENT v 15A & o
100A, MIN TRIP CURRENT v 30A & o 200A, NOM VOLTAGE 2.4 TO 23KV,
MAX INT CURRENT v 600A & o 2500A.
S34 22000 800 WESTINGHOUSE 22KV 800AMP RECLOSER YEAR OF MFR: 1984
60HZ, C.T. 6 X 1000/5. RATED INTER TIME CYCLES 3.5. TRIPPING
CONTROL VOLTAGE RANGE 14 TO 28V DC. GROUND TRIP ATTACHMENT.
CLOSING CONTROL 208 TO 254V AC. IB 38-724-1B. IL 38-726-2.

Westinghouse 22kV 800A Recloser
S443 22000 800 WESTINGHOUSE RECLOSER, 22000V 800A, RATING FREQ 60HZ, RATED MAX
KV = 27, RATED SHORT CIRCUIT AMPS (SYM) = 10,000, FW IMPULSE
WITHSTAND KV = 150, RATED INTER TIME CYCLES = 3.5, TRIPPING
CONTROL VOLTAGE RANGE = 14 TO 28VDC, CONTAINS GND TRIP
ATTACHMENT, CLOSING CONTROL VOLTAGE RANGE = 208 TO 254 VAC,
S10601 12000 560 BRUSH PMR TYPE 12KV 560AMP AUTO RECLOSER. MAKING CAP 13.1KA,
IMPULSE LEVEL 110KV. CLOSING SYSTEMS SOLENOID VOLTAGE 11KV. CT
RATIOS 200/1A. YOM 1989.
S577 12000 400 NEW TOSHIBA 1991 POLE MOUNTED VACCUUM SWITCH, MODEL VSP5-15HSAT.
12KV, 400AMP, 50/60HZ 3 POLE, SHORT TERM CURRENT 12.5KA, PEAK
MAKING CURRENT 31.5KA, BIL 95KV. OPERATING VOLTAGE 120VAC
S427 11000 150 REYROLLE 11KV 150AMP RECLOSER TYPE OYS/X2/JO, MAKING CAP 8.7,
204KG, 200/1 EARTH FAULT RELAY
NOTE NO OVERCURRENT FITTED